Tiempo: 2025-10-16
Static or dynamic
1 axis or 2 axes
Multiple signal outputs
Screw mount
Zero point setting at any position

Measurement status
Static/Dynamic
Measurement range
±15°, ±60°, ±90°, ±180°, 360°
Measuring axis
2 axes, 1 axis
Mounting method
Horizontal, Horizontal/Vertical
Measuring mode
Mode 0~4
Mass
Approx.85g
Protection degree
IP67
MTTF
10 Years @40℃
Housing material
Aluminum alloy/Plastic
Resolution
0.08°
Accuracy
±0.1°@RT
Operating temperature range
-40℃~+85℃
Storage temperature range
-40℃~+105℃
Temperature drift
0.01°/℃
Vibration
10g, 10Hz~1.5kHz
Shock
100g, 6ms (EN60068-2-27)
ESD durability
Contact discharge ±8KV,Aerial discharge ±15KV
EMS durability
100V/m (80MHz~1GHz,1KHz80% 调幅 Amplitude modulation)
EFT
GB/T 17626.4-2008/IEC61000-4-4: 2004 /Level: 4
Surge
GB/T 17626.5-2008/IEC61000-4-5: 2005 /Level: 4
Input voltage
5VDC / 9~30VDC
Output signal
Analog 0~5V, 0~10V, 4~20mA, SSI, RS232, RS422, RS485, CAN
Current consumption
<90mA @0505
Power on start-up time
<0.1s
Response time
10ms
Connection
8-core shielded jacketed cable(1m±5cm), for pin definition refer to the Terminal Connection Instructions
Filtering
Kalman filtering
Insulation resistance
≥100MΩ